A-A-975A
satisfactory level of competition without adversely affecting performance requirements or exposing suppliers’ employees to undue hazards from the recovered materials.
IV. Hazardous Material requirements.
A. Material Safety Data Sheets. Safety data shall be furnished in accordance with Fed.Std.313. The pertinent government mailing addresses for submission of data are listed in appendix B of Fed.Std.313.
V. Quality Assurance Requirements.
A. Responsibility for inspection. Unless otherwise specified in the contract or purchase order (see ordering information), the supplier is responsible for the performance of all inspection requirements as specified herein. Except as otherwise specified, the supplier shall utilize his own facilities or any commercial laboratory acceptable to the Government. The Government reserves the right to perform any of the inspections set forth in the specification where such inspections are deemed necessary to assure that supplies and services conform to prescribed requirements.
B. Lot definition. Each lot shall be inspected for conformance to the requirements herein. Inspection shall be in accordance with MIL-STD-105 using the sampling plans specified below. The lot shall be expressed in leads manufactured from the same materials at essentially the same time.
C. Examination of the end product for defects in workmanship. The sample unit for this examination shall be one filled unit container. The inspection level shall be S-2 with an Acceptable Quality Level (AQL) of 2.5 % defective expressed in terms of percent defective in accordance with MIL-STD-105.
Examine |
Defects |
Workmanship |
Not as specified. |
Material |
Not as specified. |
Hardness Marking |
Not as specified. |
D. Measurements. Inspection Level S-1 with an AQL of 2.5 percent defective, for each measurements. The sample unit shall be one lead.
Examine |
Defects |
Length |
Not as specified. |
Diameter |
Not as specified. |
Hardness |
Not as specified. |
E. Packaging, Packing, and Marking. Inspection Level S-2 with an AQL of 4.0 percent defective. The sample unit shall be one fully