A-A-1689B
2. Requirements and Test Methods
|
Requirement |
Test Method |
|||
Type I |
Type II |
|
|||
Min. |
Max. |
Min. |
Max. |
||
Adhesion oz./in. width (min.) |
15 |
___ |
15 |
___ |
ASTM D 3330 Procedure A |
Tensile lbs./in. width (min.) |
12 |
ญญ___ |
12 |
___ |
ASTM D 3759 |
Water Vapor Transmission Rate g./100 sq. in./ 24 hr. |
__ |
5.5 |
__ |
5.5 |
ASTM D 3833 |
3. Quality Assurance
Sampling for Examination and Testing shall be in accordance with Section 6 of ASTM D 3715 with an AQL of 4 percent defective. The sample unit shall be one roll of tape.
Inspection for Packaging, Packing, and Marking shall be in accordance with MIL-STD-105D and Change Notice 2 using the sampling plans specified below.
Inspection Level S-2 with an AQL of 4.0 percent defective. The sample unit shall be one fully prepared shipping container.
4. Preparation for delivery
Packaging, packing and marking of the tapes shall be as specified in the contract or purchase order.
5. Application for copies of technical documents referenced herein:
The issue date in effect on date of invitation for bids or request for proposal shall be apply.
ASTM standard test methods can be obtained from the American Society for Testing and Materials; 1916 Race Street; Philadelphia, PA 19103.
MIL-STD-105 is available from Naval Publications and Forms Center; 5801 Tabor Avenue; Philadelphia, PA, 19120.
6. Ordering Data
Purchasers should specify the type, class, width, length and color of tape desired.