A-A-2762
V. Quality assurance requirements.
A. Responsibility for inspection. Unless otherwise specified in the contract or purchase order (see VIII), the supplier is responsible for the performance of all inspection requirements as specified herein. Except as otherwise specified, the supplier may utilize his own facilities or any commercial laboratory acceptable to the Government. The Government reserves the right to perform any of the inspection set forth in the specification where such inspections are deemed necessary to assure that supplies and services conform to prescribed requirements.
B. Lot definition. Each lot of typing elements shall be inspected for conformance to the requirement herein. Inspection shall be in accordance with MIL-STD-105 using the sampling plans specified below. The lot shall be expressed in typing elements manufactured from the same materials, at essentially the same time.
C. Examination of the end item for visual defects. The sample unit for this examination shall be one typing element. A random sample shall be taken from each lot in accordance with Inspection Level S-3. The AQL shall be 2.5 percent defective samples shall be examined for defects listed below. My typing element containing one or more defects shall be rejected.
Examine |
Defects |
Typing Element |
Not compatible with machine specified |
Quality |
Not as specified |
Material |
Not as specified |
Workmanship |
See Workmanship paragraph |
D. Examination of the end item for dimensional defects. The sample unit for this examination shall be one typing element. A random sample shall be taken from each lot in accordance with Inspection Level S-2. The AQL shall be 4.0 percent defective. Samples shall be examined for defects listed below. My typing element containing one or more defects shall be rejected.
The examination for the characteristics listed in the following table will be based on the specifications/requirements obtained from the OEM for the specific typing elements being examined.
Examine |
Defects |
OEM specifications |
Not as specified |
E. Sampling of the end items for performance tests. The sample unit shall be one typing element. The sample from each lot in accordance with Inspection Level S-1. The AQL shall be 2.5 percent defective.